The LTC600-SFC is a high-performance closed-loop Hall-effect current sensor from the LEM Group. It has a rated current of 500 A and is designed for precise electronic measurement of DC, AC, and pulsed currents. With excellent electrical isolation, the sensor provides a reliable safety barrier between the primary (high-power) circuit and the secondary (electronic) circuit. It is widely used in demanding applications such as industrial automation, renewable energy, rail transport, and power management where high accuracy and reliability are essential.
|
Parameter |
Value |
|
Rated current (IPN) |
500 A r.m.s. |
|
Measuring range (@24 V) |
0 … ±1500 A |
|
Secondary output signal |
100 mA (1:5000 ratio) |
|
Supply voltage |
±15 V … ±24 V (±5 %) |
|
Maximum current consumption |
< 30 mA (@ ±24 V) |
|
Accuracy (@25 °C) |
±0.7 % |
|
Linearity |
±0.1 % |
|
Response time |
< 1 µs (at 90 % of IPN) |
|
Frequency bandwidth (-1 dB) |
DC … 100 kHz |
|
Di/dt accurately followed |
> 100 A/µs |
|
Operating temperature |
–40 °C … +85 °C |
|
Insulation test voltage (50 Hz, 1 min) |
13.4 kV r.m.s. |
|
Mass |
800 g |
Unlike traditional open-loop solutions, the LTC600-SFC uses closed-loop (compensated) Hall-effect current sensing. A secondary coil generates a compensation magnetic field that cancels the field produced by the primary current, keeping the magnetic core in a zeroflux state. This results in very low thermal drift and excellent linearity (±0.1 %) over a wide temperature range – performance that openloop designs cannot match.
With a bandwidth from DC to 100 kHz, the LTC600-SFC faithfully reproduces current waveforms for DC, mains-frequency AC, and high-frequency pulsed signals. The response time is < 1 µs and the di/dt following capability exceeds 100 A/µs. Even during fast transients such as inverter switching or motor startup surges, the sensor delivers an accurate output signal without any “blind” period.
High-strength electrical isolation is provided between primary and secondary circuits. The insulation test voltage (50 Hz, 1 min) is 13.4 kV r.m.s., and the partial discharge extinction voltage is > 2.8 kV. In highvoltage applications such as UPS, switch-mode power supplies, and welders, the LTC600-SFC safely converts the high-power primary current into a low-current signal while eliminating any threat to the control electronics. The insulating case meets UL 94-V0 flameretardant rating, further increasing safety.
In industrial and power electronic environments, noise and interference are major enemies of measurement accuracy. Thanks to the closed-loop magnetic balance principle, the LTC600-SFC offers high immunity to external stray magnetic fields. Integrated shielding further suppresses electromagnetic interference, ensuring clean and reliable output signals.
The sensor works by magnetic coupling, adding zero insertion loss to the primary circuit. In high-current systems, every watt of saved loss means lower heat generation and higher system efficiency. In addition, the LTC600SFC can withstand instantaneous current peaks up to ±1500 A without damage.
The LTC600-SFC meets diverse measurement needs across industrial, energy, and transport sectors:
AC variable speed drives and servo motor drives – precisely monitor inverter input/output current for vector control and torque adjustment.
DC motor drive static converters – perform critical current measurement in DC speed control systems and reversible rectifiers.
Battery-powered applications – monitor battery charge/discharge current in real-time for state-of-charge management and overcurrent protection.
Uninterruptible power supplies (UPS) – track input/output currents, ensuring protection of critical loads during power switching.
Switch-mode power supplies (SMPS) – monitor key node currents to assist design and fault diagnosis.
Welding power sources – measure welding current in real-time for closed-loop current control.
Railway equipment – compliant with EN 50155 railway standard; used in traction converters and auxiliary power supplies.
Accurate – ±0.7 % overall accuracy, ±0.1 % linearity; high-fidelity output from closed-loop Hall technology.
Fast – 1 µs response time, 100 kHz bandwidth, > 100 A/µs di/dt following – ready for transient currents.
Reliable – wide operating temperature (–40 °C to +85 °C), multiple electrical isolation barriers, EN 50155 railway compliance.
Safe – UL 94-V0 case, high-strength primary-secondary isolation, zero insertion loss.
Versatile – from AC drives to DC drives, from UPS to welders, from battery supplies to railway – one sensor covers it all.
| Our advantage is that we not only low prices, but we more suited to you. Our Keywords is New and original parts Fast Delivery Instock & available Short Leadtime 30-Days returns ISO9001 Certification 1 Year Warranty |
|
Q: I want to work with MacroQuest because of high quality. But I found your price too high and out of line with the prevailing market level, how should I do?
A: MacroQuest has been devoted to offer a best price to our customers,if you want to buy it at a cheapper price. Please contact us directly to see if we can negotiate a cheaper price rate. Or, send us an email with your T/P.
Simon Hsu
simon@mymacroquest.com
Alice Wang
alice@mymacroquest.com
Q: Can MacroQuest offer NET terms?
A: Yes we can. Please contact with your sales manager for more information.
Q: How to Request a Quote?
-A:You have three ways to request a quote:
1.Choose an item using a search box or browsing through product categories.Click on "Request Quote" button on the Product page.
2.Click here for feedback on our web.
3.If you have a BOM list or want to email us directly, please contact:
Simon Hsu
simon@mymacroquest.com
Alice Wang
alice@mymacroquest.com
Q:Are all the parts new and original?
-A:Yes, all parts are new and original checked by our quality control department.
Q:How long is your warranty?
-A:We offer a 1 year warranty for form fit and function for MacroQuest stock.
Q: Can I use Credit Card/Debit Card payment for my orders on your website?
-A:Yes, you can. you can pay on our company via Credit Card/Debit Card(Mastercard, Discover, Visa, American EXpress, Diners).
Please select the first payment method-Paypal, then you will see Credit Card/Debit Card payment button in the lower right corner.
My Account
If you visit our website for the first time or do not have your login and password yet, please complete the new Customer Registration Form and register in our Customers’ database.
If you have an account, enter your login and password and confirm these with the “Log in” button.
If necessary, complete the contact person identification form.
Log In / Registration
Update Profile Information
Change Password
Update Addresses
Update Payment Cards
Update Order Preferences
Update Product Notifications
Product Information
Choose an item using a search box or browsing through product categories. While searching, you can use your own previously entered product symbols/references.
Searching for Products
Pricing & Availability
Packaging Options
RoHS / Legislation
Technical Support
Placing Orders
How to place an order if you have an account at MacroQuest?
Checkout
Invoicing & Payment
Delivery Information
Favourite
Parts List (BOM) Upload
Trade Account
Quotes
Quick Buy
Saved Shopping Baskets
Scheduled Orders
Vouchers
Viewing and Changing Orders
The on-line orders system within the MacroQuest’s service works at real time, thanks to which it is immediately (at the moment of placing the order) possible to make a reservation for the selected product in the warehouse what it will be automatically noted in the on-line service.
If you order a product, it will be reserved for you.
You can make changes in quantity in the cart, by adding and removing items from the not closed order, before you direct them to realization with the “finish the order” button.
Order Status & Tracking
Request an Invoice
Cancel an Order
Returning a Product
RMA# is required for all returns. They are issued for returns that are within 30 days of the initial purchase.
Return Policy
How to Return a Product